Question 1 of 5 Sensors Standard Probes (up to 3 — 1/3 selected) Contacting Conductivity pH ORP Contacting Conductivity Select at least one standard probe to continue. Add-On Probe (select up to 1) None None PTSA PTSA + Poly Turbidity TTA Select the PTSA probe brand: Pyxis Pyxis Turner Select desired PTSA range: 0-200ppb (Pyxis-ST-500, default) 0-200ppb (Pyxis-ST-500, default) 0-500ppb (Pyxis-ST-500-500) Select desired PTSA+Poly probe: Pyxis ST-588 Pyxis ST-588 Select desired Turbidity range: 0-100 NTU (ST-730, default) 0-10 NTU (ST-731) 0-100 NTU (ST-730, default) 0-1,000 NTU (ST-730B) 0-10,000 NTU (ST-735) Flow Switch Walchem Flow Switch Walchem Flow Switch Disinfection Probe (select up to 1) None Free Cl Total Cl Stabilized Bromine Select the Free Cl probe brand: Walchem Pyxis Select the free chlorine probe style: Non-Membrane Membrane Select desired Free Cl range: 0-20 PPM (191445, default) 0-2 PPM (104274) Select the Total Cl probe brand: Walchem Pyxis Select desired Total Cl range: 0-20 PPM (104165, default) 0-2 PPM (104258) Select desired Stabilized Bromine range: 0-20 PPM (104319, default) 0-2 PPM (104318) Question 1 of 5 Corrosion Monitoring Coupon Rack No No Yes Select Coupon Rack Style: Solid Solid Clear Coupons (select desired quantity) 1 2 3 4 Corrators No No Yes Select the Corrator brand/style: Select an option Walchem LPR (I9 Only) Pyxis CR-300 Corrator Quantity (select desired quantity) 1 2 3 4 Select electrode tip material (up to 0, one of each) Select electrode tip materials Carbon Steel Copper Brass Select the Pyxis CR-300 wiring style: Standard Wiring - General + Localized Corrosion Standard Wiring - General + Localized Corrosion(2 Analog Inputs) Basic Wiring - General Corrosion Only(1 Analog Input) Select electrode tip material Carbon Steel, Copper Carbon Steel Copper Flow Monitoring & Control Flow Control Valve No No Dole Valve Globe Valve Coupons require a flow-control selection. Choose a Dole Valve or Globe Valve to continue. Dole Valve GPM: Select an option 8 GPM Rotometer No No Yes Select Rotometer Max Range: 10 GPM 10 GPM 20 GPM Panel Layout & Options Inlet Direction Left Left Right Outlet Direction Left Left Right Modifiers (panels include a 1" clear strainer by default) None None 1" Strainer (Opaque) Check Valve Motorized Blowdown Valve Question 1 of 5 Pumps & Injection Pump Shelf on Panel No No Yes Pump Shelf Size (select desired capacity) 1 2 3 4 Injection Points on Panel No No Yes Injection Points (select desired quantity) 1 2 3 4 Add Pumps to Order No No Yes Pump Models (maximum 4 pumps total) Standard EWP-045BPA07N-USL EWP-L Pump | 0.7 GPH | 150 PSI | GFRPP | Valve Balls: CE | Seats: PCTFE | Seals: AFLAS® | Gaskets/Diaphragm: PTFE | 3/8 in Tubing | 115V 0 EWP-075CPA07N-USL EWP-L Pump | 1.2 GPH | 105 PSI | GFRPP | Valve Balls: CE | Seats: PCTFE | Seals: AFLAS® | Gaskets/Diaphragm: PTFE | 3/8 in Tubing | 115V 0 EWP-045BPA07N-USR EWP-R Pump | 0.7 GPH | 150 PSI | GFRPP | Valve Balls: CE | Seats: PCTFE | Seals: AFLAS® | Gaskets/Diaphragm: PTFE | 3/8 in Tubing | 115V 0 EWP-075CPA07N-USR EWP-R Pump | 1.2 GPH | 105 PSI | GFRPP | Valve Balls: CE | Seats: PCTFE | Seals: AFLAS® | Gaskets/Diaphragm: PTFE | 3/8 in Tubing | 115V 0 Auto Degassing EWP-035BVC07A-USL EWP-L Pump | 0.6 GPH | 150 PSI | PVC | Valve Balls: CE | Seats: FKM | Seals: FKM | Gaskets/Diaphragm: PTFE | 3/8 in Tubing | 115V | Auto Degassing Valve 0 EWP-035BVC07A-USR EWP-R Pump | 0.6 GPH | 150 PSI | PVC | Valve Balls: CE | Seats: FKM | Seals: FKM | Gaskets/Diaphragm: PTFE | 3/8 in Tubing | 115V | Auto Degassing Valve 0 0 of 4 pumps selected. Question 1 of 5 Connectivity Cell Modem No No Yes Controller Comms None Modbus/BACnet WiFi (I9 Only) Question 1 of 5 How many pumps? Choose 1, 2, or 4 chemical feed pumps. 1 pump 2 pumps 4 pumps Question 1 of 5 Are all pumps the same model? If all pumps use the same stocked SKU, one selection applies to all. Yes No Question 1 of 5 Do you need a pump shelf? This is independent of pump selection. Yes No Question 1 of 5 What size pump shelf? 1 2 3 4 Question 1 of 5 Need injection points? Yes No Question 1 of 5 How many injection points? Choose 1 to 4 injection points. 1 injection point 2 injection points 3 injection points 4 injection points Question 1 of 5 Do you need 1" coupons? Yes No Question 1 of 5 How many coupons? 1 2 3 4 Question 1 of 5 Clear coupon holders? Yes No Question 1 of 5 Do you need flow control? Yes No Question 1 of 5 What kind of flow control? Globe valve Dole Valve (8 GPM) Question 1 of 5 Inlet Left Right Question 1 of 5 Outlet Left Right Question 1 of 5 Do you need a rotometer? Yes No Question 1 of 5 What kind of rotometer? Select rotometer option 1 - 10 GPM 2 - 20 GPM Question 1 of 5 Modifiers None 1" Strainer (Opaque) Check Valve Motorized Blowdown Valve Question 1 of 5 Do you need a cell modem? Adds modem hardware to the controller and includes a cellular data service line item. Required for remote monitoring over a cellular connection. Yes No Question 1 of 5 What kind of communications do you need? Ethernet and Modbus are independent of the cell modem — they do not add modem hardware or service. No wired communications Ethernet only Ethernet + Modbus / BACnet Question 1 of 5 Order Summary SelectionPart / Configuration NumberQtyAlternativeDocs ACT Panel Number ACT-61NW-N7N-LLNNNN 1 − 2D Drawing Controller I6 I9 I6W.00000000000VO1 (WCT6A00PANNN-NNNNN) 1 − Customize I6 controller Relays Auto — A00 Auto — A00 000 — 6 Pwd - No Pigtails 100 — 2 Pwd/4 Dry - No Pigtails 200 — 2 Opto/4 Dry - No Pigtails 400 — 4 Opto/2 Dry - No Pigtails B00 — 2 Pwd/4 Dry - Pigtails C00 — 2 Opto/4 Dry - 20' Pulse Cables D00 — 4 Opto/2 Dry - 20' Pulse Cables Power Cord Auto — P Auto — P B — Brazil Power Cord 15A D — DIN Power Cord 15A H — Hardwired I/O Card 1 Auto — A Auto — A N — No Input Card B — Dual Channel Analog Input C — Combo Sensor Analog Input I/O Card 2 Auto — N Auto — N A — Sensor Input B — Dual Channel Analog Input C — Combo Sensor Analog Input Analog Out Auto — N Auto — N A — 2 Analog Outputs Ethernet Auto — N Auto — N E — Ethernet Board M — Ethernet Board w/ Modbus TCP+BACnet Use automatic selection Done Data Sheet Manual Conductivity Probe W600-CT-IANNN 1 − − W600-CT-IBNNN Data Sheet Manual Warning: Selected Pump Quantity (0) exceeds the capacity of the selected Pump Shelf (0). Warning: Selected Pump Quantity (0) exceeds the selected number of Injection Points (0). Note: Double-check the selected configuration to make sure the panel setup is as intended. Back Add to Cart Review